Note |
|
Description of single unit |
|
|
|
Construction |
Interlock height |
: 945 |
|
Interlock length |
: 2010 |
|
Passage width
|
: 650 |
|
Total width |
: 1070 |
|
Housing, base columns, guiding elements |
: Rectangular stainless steel posts AISI 304 with 10 mm
toughened satined glass panel and stainless steel bar
handle AISI 304 as well as vertical and horizontal
sensors mounted on the guiding elements. |
|
Barrier elements |
: Door wings made of transparent polycarbonate |
|
|
: Rotation angle monitored by separation sensors. |
|
|
|
Finish |
|
: Stainless steel satin finish. |
|
|
|
Function |
|
: Type 2 * |
|
Drives |
: Integrated in the rotating tube |
|
: Security level 2. Entrance sector monitored by
enhanced sensor system in optimized overall length
and adjustment (increased level of single passage
regulation in both directions). Integrated sneak-by
guard, detection of children and trolley cases. |
|
Operation modes |
: Open or closed.** |
|
|
|
Electrical components |
|
: ETS 21, control system and power supply integrated in
the unit. |
|
|
: Power supply 110 – 230 VAC, 50/60 Hz. |
|
|
: Standby power consumption 17 VA. |
|
Standard adjustment in case of power failure |
: Barrier elements can be moved freely. |
|
|
|
Installation |
|
: Dowelled on finished floor level FFL |
|
|
: Not suitable for outdoor installation! |