Note |
|
Description of single unit |
|
|
|
Construction |
Interlock height |
: 945 |
|
Interlock length |
: 2010 |
|
Passage width
|
: 650 |
|
Total width |
: 1070 |
|
Housing, base columns, guiding elements |
: Stainless steel tube AISI 304 Ø 60 mm with
10 mm toughened glasspanel and stainless
steel bar handle AISI 304 as well as
vertical andhorizontal sensors mounted on
the guiding elements. |
|
Barrier elements |
: Door wings made of transparent
polycarbonate |
|
|
: Rotation angle monitored by separation
sensors. |
|
|
|
Finish |
|
: Stainless steel satin finish. |
|
|
|
Function |
|
: Type 2 * |
|
Drives |
: Integrated in the
rotating tube |
|
|
: Security level 2. Entrance sector monitored
by enhanced sensor system in
optimizedoverall length and adjustment
(increased level of single passage
regulation
in both directions). Integrated sneak-by
guard, detection ofchildren and trolley
cases. |
|
Operation modes |
: Open or closed.** |
|
|
|
Electrical components |
|
: ETS 21, control system and power supply
integrated in the unit. |
|
|
: Power supply 110 – 230 VAC, 50/60 Hz. |
|
|
: Standby power consumption 17 VA. |
|
Standard adjustment in case of power failure |
: Barrier elements can be moved freely. |
|
|
|
Installation |
|
: Dowelled on finished floor level FFL.
|
|
|
: Not suitable for outdoor installation! |