Featured

The high capacity, feature-rich VISTA-20P lets you deliver more value to your customers on each and every sale with up to 48 zones of protection, Internet  uploading/downloading, graphic keypad support and dual partitions. VISTA-20P gives you the ability to send alarm signals and upload/download via an Internet Protocol (IP), improving the speed at which information can be delivered to and from the control panel.

In addition, the VISTA-20P, used with an AlarmNet® Internet or 4G communicator can be installed in premises without TELCO lines. The panel’s installation advantages, innovative end-user benefits and robust system capacity make the value-priced VISTA-20P an ideal choice for higher end installations.

  • IP alarm reporting and uploading/
    downloading capability for Internet and
    Intranet use via iGSMV4G, 7845i-ENT,
    GSMV4G or GSMX4G
     
  • Supports four graphic
    touchscreen keypads
  • Wireless keys can be programmed
    without using zones
  • Eight on-board hardwired zones
    standard (15 when Zone Doubling
    feature is used)
    – 40 hardwire expansion zones
    – 40 wireless expansion zones
  • Two low current on-board
    trigger outputs
  • 100 Event Log viewable at system
    keypads with time/date stamp
  • 48 system user codes assignable to
    either partition
  • Expandable to 48 total zones when
    used with hardwired and/or wireless
    expansion modules
  • Two independent partitions plus a
    common partition
    • Global Arming from any
      system keypad
    • Go to function to view or operate
      one partition from the other
    • Separate partition account numbers
  • 16 output devices
    • Relays (Model 4204 Relay Modules,
      or 4229 Expansion Module)
  • Four installer-configurable zone
    types allows the installer to create
    custom zone types by assigning
    all zone attributes
  • Supports four-wire and up to
    16 two-wire smokes
    • Works with Sentrol CleanMe™
      maintenance signal
  • Multiple actions on output devices
    depending on system state
    • Turns lights off when system arms
    • Turns the same light on when
      system disarms
    • Flashes same lights when system
      is in alarm
  • Built-in phone line cut monitor
    with programmable delay and
    annunciation options
    • Display on system keypads
    • Trigger local sounders
    • Trigger system bell
Security Dealer Features
  • Automatic System Load Shed
    • During extended AC power fail,
      the system battery will be
      disconnected to prevent irreversible
      battery failure. Reduces service
      calls to replace batteries.
  • Dynamic Signaling
    • Reduces redundant reporting to
      the central station when multiple
      reporting methods are used; i.e.
      digital dialer and AlarmNet radio
Valuable End-user Features
  • Viewable on system keypads:
    • Exit countdown
    • Time and date display*
    • Event log*
  • Auto keypad backlighting on entry
  • Keyswitch arming
  • Programmable macro buttons and
    single-button arming
  • Supports a variety of wireless remote
    controls for single-button operation
  • User Scheduling
    • Latchkey reports to pagers
    • Auto arm/disarm
    • “User access” time windows
  • VIP Module allows system control
    from any touchtone phone
  • Chime by zone
  • Fully compatible with Honeywell Total
    Connect™ Remote Services

    *Requires custom alpha keypad

Specification

Electrical
  • Aux. power 12VDC, 600mA maximum
  • Seven hour standby at 400mA aux.
    load with four amp hour battery
  • 16.5VAC/25VA transformer
  • Alarm output 12VDC, 2.0 amps max.
    • For UL installations, combined aux. and
      alarm output cannot exceed 700mA
      Output Control
  • Supports up to four relay boards
    (up to 16 relays)
  • Optional X-10 transformer/interface
    (part no. 4300) may be used to control
    up to 16 X-10 receiving devices

Zones

  • Eight hardwired zones
    (15 with zone doubling)
  • Selectable response 10msec,
    350msec, 750msec
  • Assignable to any partition
  • 20 selectable zone types plus four
    configurable zone types
  • Programmable swinger suppression

Expansion Devices

  • 4219 – Eight hardwired zones – 16mA
  • 4204 – Up to four relays – 15mA standby
    (each active relay draws an
    additional 40mA)
  • 4229 – Eight hardwired zones and two
    relays – 36mA (each active relay
    draws an additional 40mA)

Accessories

  • iGSMV4G Internet and Digital
    Cellular Communicator with
    Remote Service Capability
  • 7845i-ENT Enterprise
    Internet Communicator
  • GSMV4G Digital Cellular Communicator
    with Remote Service Capability
  • GSMX4G Digital Cellular Communicator for
    VISTA Control Panels
  • 5881ENL RF Receiver supports
    up to eight zones – 60mA
  • 5881ENM supports up to
    16 zones – 60mA
  • 5881ENH supports up to
    48 zones – 60mA
  • 5883 Transceiver supports up to
    40 zones – 80mA

Keypads

  • 6162 Custom Alpha Security Keypad
    – 40mA/120mA
  • 6162V Voice Custom Alpha Security
    Keypad – 60mA/190mA
  • 6162RF Custom Alpha Receiver/Security
    Keypad – 120mA/210mA
  • 6152 Fixed-English Security Keypad
    – 40mA/70mA
  • 6152V Voice Fixed-English Security
    Keypad – 60mA/190mA
  • 6152RF/6152RFFR Fixed-English/French
    Receiver/Security Keypad – 80mA/105mA
  • 6152ZN/6152ZNFR Fixed-English/French
    Security Keypad with Hardwired Zone
    – 35mA/80mA
  • 6148 Fixed English LCD – 30mA/55mA
  • 6280 Color Graphic Touchscreen
    Keypad with Voice
  • Tuxedo TouchTM (TUXW) Color Graphic
    Voice Touchscreen Security Keypad and
    Home/Business Controller (White)
  • Tuxedo Touch with Integrated Wi-Fi®
    (TUXWIFIW) Color Graphic Voice
    Touchscreen Security Keypad and
    Home/Business Controller with
    Integrated Wi-Fi (White)

 

Agency Listings
ETL listing

  • Residential Fire and Burglary:
    • Household Fire Warning System
      Units – ANSI/UL 985, 2000/05/26
      (5th edition) with revisions

Smoke Detectors

  • Supports up to 16 two-wire smoke
    detectors
  • Supports four-wire smoke detectors

Communications

  • iGSMV4G Internet and Digital Cellular
    Communicator with Remote Service
    Capability
  • 7845i-ENT Enterprise Internet
    Communicator
  • GSMV4G Digital Cellular Communicator
    with Remote Service Capability
  • GSMX4G Digital Cellular Communicator for
    VISTA Control Panels
  • Touchtone or pulse
  • Formats supported
    • ADEMCO® Contact ID
    • – ADEMCO 4 + 2 Express
    • – ADEMCO low speed
    • – Sescoa/Radionics
  • 3 + 1, 4 + 1 and 4 + 2 reporting
  • Reporting capabilities
    • – Split
    • – Dual
    • – Split/Dual – True dial tone detection
  • Low battery reports 11.2 – 11.6VDC
  • AC loss and restoral reporting supported
   