Honeywell VISTA-20P
PRODUCT HIGHLIGHT
|
Featured
The high capacity, feature-rich VISTA-20P lets you deliver more value to your customers on each and every sale with up to 48 zones of protection, Internet uploading/downloading, graphic keypad support and dual partitions. VISTA-20P gives you the ability to send alarm signals and upload/download via an Internet Protocol (IP), improving the speed at which information can be delivered to and from the control panel.
In addition, the VISTA-20P, used with an AlarmNet® Internet or 4G communicator can be installed in premises without TELCO lines. The panel’s installation advantages, innovative end-user benefits and robust system capacity make the value-priced VISTA-20P an ideal choice for higher end installations.
- IP alarm reporting and uploading/
downloading capability for Internet and
Intranet use via iGSMV4G, 7845i-ENT,
GSMV4G or GSMX4G
- Supports four graphic
touchscreen keypads
- Wireless keys can be programmed
without using zones
- Eight on-board hardwired zones
standard (15 when Zone Doubling
feature is used)
– 40 hardwire expansion zones
– 40 wireless expansion zones
- Two low current on-board
trigger outputs
- 100 Event Log viewable at system
keypads with time/date stamp
- 48 system user codes assignable to
either partition
- Expandable to 48 total zones when
used with hardwired and/or wireless
expansion modules
- Two independent partitions plus a
common partition
- Global Arming from any
system keypad
- Go to function to view or operate
one partition from the other
- Separate partition account numbers
|
- 16 output devices
- Relays (Model 4204 Relay Modules,
or 4229 Expansion Module)
- Four installer-configurable zone
types allows the installer to create
custom zone types by assigning
all zone attributes
- Supports four-wire and up to
16 two-wire smokes
- Works with Sentrol CleanMe™
maintenance signal
- Multiple actions on output devices
depending on system state
- Turns lights off when system arms
- Turns the same light on when
system disarms
- Flashes same lights when system
is in alarm
- Built-in phone line cut monitor
with programmable delay and
annunciation options
- Display on system keypads
- Trigger local sounders
- Trigger system bell
Security Dealer Features
- Automatic System Load Shed
- During extended AC power fail,
the system battery will be
disconnected to prevent irreversible
battery failure. Reduces service
calls to replace batteries.
|
- Dynamic Signaling
- Reduces redundant reporting to
the central station when multiple
reporting methods are used; i.e.
digital dialer and AlarmNet radio
Valuable End-user Features
- Viewable on system keypads:
- Exit countdown
- Time and date display*
- Event log*
- Auto keypad backlighting on entry
- Keyswitch arming
- Programmable macro buttons and
single-button arming
- Supports a variety of wireless remote
controls for single-button operation
- User Scheduling
- Latchkey reports to pagers
- Auto arm/disarm
- “User access” time windows
- VIP Module allows system control
from any touchtone phone
- Chime by zone
- Fully compatible with Honeywell Total
Connect™ Remote Services
*Requires custom alpha keypad
|
Specification
Electrical
- Aux. power 12VDC, 600mA maximum
- Seven hour standby at 400mA aux.
load with four amp hour battery
- 16.5VAC/25VA transformer
- Alarm output 12VDC, 2.0 amps max.
- For UL installations, combined aux. and
alarm output cannot exceed 700mA
Output Control
- Supports up to four relay boards
(up to 16 relays)
- Optional X-10 transformer/interface
(part no. 4300) may be used to control
up to 16 X-10 receiving devices
Zones
- Eight hardwired zones
(15 with zone doubling)
- Selectable response 10msec,
350msec, 750msec
- Assignable to any partition
- 20 selectable zone types plus four
configurable zone types
- Programmable swinger suppression
Expansion Devices
- 4219 – Eight hardwired zones – 16mA
- 4204 – Up to four relays – 15mA standby
(each active relay draws an
additional 40mA)
- 4229 – Eight hardwired zones and two
relays – 36mA (each active relay
draws an additional 40mA)
Accessories
- iGSMV4G Internet and Digital
Cellular Communicator with
Remote Service Capability
- 7845i-ENT Enterprise
Internet Communicator
|
- GSMV4G Digital Cellular Communicator
with Remote Service Capability
- GSMX4G Digital Cellular Communicator for
VISTA Control Panels
- 5881ENL RF Receiver supports
up to eight zones – 60mA
- 5881ENM supports up to
16 zones – 60mA
- 5881ENH supports up to
48 zones – 60mA
- 5883 Transceiver supports up to
40 zones – 80mA
Keypads
- 6162 Custom Alpha Security Keypad
– 40mA/120mA
- 6162V Voice Custom Alpha Security
Keypad – 60mA/190mA
- 6162RF Custom Alpha Receiver/Security
Keypad – 120mA/210mA
- 6152 Fixed-English Security Keypad
– 40mA/70mA
- 6152V Voice Fixed-English Security
Keypad – 60mA/190mA
- 6152RF/6152RFFR Fixed-English/French
Receiver/Security Keypad – 80mA/105mA
- 6152ZN/6152ZNFR Fixed-English/French
Security Keypad with Hardwired Zone
– 35mA/80mA
- 6148 Fixed English LCD – 30mA/55mA
- 6280 Color Graphic Touchscreen
Keypad with Voice
- Tuxedo TouchTM (TUXW) Color Graphic
Voice Touchscreen Security Keypad and
Home/Business Controller (White)
- Tuxedo Touch with Integrated Wi-Fi®
(TUXWIFIW) Color Graphic Voice
Touchscreen Security Keypad and
Home/Business Controller with
Integrated Wi-Fi (White)
|
Agency Listings
ETL listing
- Residential Fire and Burglary:
- Household Fire Warning System
Units – ANSI/UL 985, 2000/05/26
(5th edition) with revisions
Smoke Detectors
- Supports up to 16 two-wire smoke
detectors
- Supports four-wire smoke detectors
Communications
- iGSMV4G Internet and Digital Cellular
Communicator with Remote Service
Capability
- 7845i-ENT Enterprise Internet
Communicator
- GSMV4G Digital Cellular Communicator
with Remote Service Capability
- GSMX4G Digital Cellular Communicator for
VISTA Control Panels
- Touchtone or pulse
- Formats supported
- ADEMCO® Contact ID
- – ADEMCO 4 + 2 Express
- – ADEMCO low speed
- – Sescoa/Radionics
- 3 + 1, 4 + 1 and 4 + 2 reporting
- Reporting capabilities
- – Split
- – Dual
- – Split/Dual – True dial tone detection
- Low battery reports 11.2 – 11.6VDC
- AC loss and restoral reporting supported
|
|